About Spare Parts
Spare parts are available for products we manufacture. Select the quote option on the menu bar to submit the information on the product. There are some parts we do not offer such as fluorescent lamps, motors and ballasts. The following information should be helpful in obtaining these parts.
Purchase replacement motors from Grainger at grainger.com
1/4HP, 4M096
1/3HP, 4M098
1/2HP, 4M100
The motor has a label which will list the HP. To
see this label, you will need to loosen the set
screw on the shaft side of the blower and loosen
the motor mounting band on the opposite side of
the set screw and slide the motor out about 1 to
3 inches to expose this label. Replace the motor
run capacitor anytime a motor is replaced. The
capcitor size is listed in the specification data for the motor on the Grainger site.
Fluorescent lamps are T12 single pin linear tubes. Lamps can be purchased by the
case (typically 15) from 1000bulbs.com or other lighting supply vendors.
F36T12CW, three-foot workstation/module
F48T12CW, four-foot workstation/module
F60T12CW, five-foot workstation/module
F72T12CW, six-foot workstation/module
F96T12CW, eight-foot workstation/module
In June 2012 we switched from the T12 to the T5 bi-pin fluorescent linear tubes for
the B, C and TM series. Lamps can be purchased by the case
(typically 40) from 1000bulbs.com or other lighting supply vendors.
F24T5/HO, four and five-foot workstation/module
F39T5/HO, five and six-foot workstation/module
F54T5/HO, eight-foot workstation/module
For Pure Aire laminar flow products that have lighting using fluorescent tubes: This
system uses a ballast which regulates the current and provides the voltage
required to start the lamps. The Advanced ballast SM-2E40-S-TP and
R-2E75-S-TP used in our workstations were discontinued by Pure Aire June 2011
and may be obsolete. The current ballast being used with the T12 lamps is the
GE-260-IS-MV-N. This ballast can be used to replace the above ballast but the
wiring will need to be changed. It is
recommended an electrician be
contracted to perform this work(linked
below). If the workstation has the
GE-260-IS-MV-N ballast replacing is simplified. For workstations/modules using
the T5 lamps the ballast being used is the WH3-120, (3 & 4 foot units) WH5-120 (5
and 6 foot units) and the WH7-120. (8 foot units) These ballast can purchased from
zoro.com, 1000bulbs.com or amazon.com to list a few.